38.107.179.23238.107.179.232 Network Management Software - InterMapper Customer Support
InterMapper.comiMapper Community 
 
Network Management Software - InterMapper Customer Support
Wireless Monitoring Probes

Wireless monitoring probes developed by the InterMapper Community include:

Tranzeo CPQ Probe [.zip] [ view ]
Reports Antenna Type, Firmware, Connected AP MAC Address, Signal Strength, Noise, Connected SSID, and Total Bytes In/Out. It issues all warnings from the SNMP Traffic probe and alerts on Low Signal, High Signal, and Low Transfer rate.

Ubiquiti CPE Probe [.zip]
[ view ]
Reports Antenna Type, Firmware, Device MAC Addresses, Connected AP MAC Address, Signal Strength, TX/RX Rate, Connected SSID, Total Bytes In/Out. It issues warnings for Low Signal, High Signal, and Low Transfer rate.

Redline AN-80 Probe [.zip]

Probes a Redline AN-80 point-to-point radio, acting as either a master or slave, to retrieve and display a number of critical statistics for the radio, and give alarms based on user-specified thresholds.

DragonWave AirPair Probe [.zip]
Monitors Serial Number, AP Type, Modem Sync LED, Rx Cable Loss, Tx Cable Loss, RSL, and BER. Tim also provides the MIB for the radio along with the probe.

Breezecom Wireless Devices [.zip]
Monitors Breezecom line of equipment from Alvarion.




 

 
UPS Monitoring Probes

UPS monitoring probes developed by the InterMapper Community include:

MGE EPC 6000 Series UPS Probe [.zip]
Monitors an MGE EPC 6000 UPS with a UM-Link Ethernet interface, including phases B and C.

APC PDU Probe [.zip]
Monitors 3-phase APC rack-mount PDUs. The probe checks all three phases for load plus current for each of the individual phases. Warning, alarm and critical thresholds can be set for current.

Liebert AirCon [.zip]
Polls an AirCon for its alarm settings and current readings, and allows user-specified pre-alarm (warning) and critical values.

APC Silcon UPS Probe [.zip]
Reports status conditions for APC Silcon UPS. It's geared for a three-module N+1 setup on 208v power, and warns about load when you are in danger of going out of redundancy (as opposed to reaching the one-module tolerances), but the thresholds are fully adjustable.

Liebert 600 UPS Probe [.zip]
Monitors the SCC and static switch of the Liebert 600 UPS.

Sentry 3 CDU Probe [.zip]

Monitors Sentry 3 CDU. This probe is based on two infeeds, each with two branches (AA, AB, BA, BB) and does give false alarms for CDUs with one infeed (AA, AB) since it can't communicate with the B tower.

BestPower Uninterruptible Power Supply [.zip]
Monitors a BestPower Uninterruptible Power Supply (UPS).

Basic Monitoring for MGE Pulsar EXL5 UPS [.zip]
Monitors an MGE "Pulsar EXL5" UPS with a UM-Link Ethernet interface via SNMP. (Note: The probe can be used as a starting point for the design of similar probes for other models from MGE, but this implementation assumes a single phase/single receptacle unit (i.e. it only looks at the first entry in tables that index on phases or receptacles) and has only been tested on an EXL5 UPS.)




 

 
Telecommunications Monitoring Probes

Telecommunications monitoring probes developed by the InterMapper Community include:

Motorola DSR 4520 Probe [.zip]
Monitors signal status, LED status, and device alarm state. The probe will alarm on device alarm state, triggered alarms and alarm bypass mode.

Scientific Atlanta D9850 Probe [.zip]
Queries for current program number, safe signal state, bit error ratio, signal to noise ratio, signal level, AFC level, and video bitrate. The device will alarm on safe signal state, safe signal ratio and safe signal level.

Adtran DSLAM Probe [.zip]
Scans the Adtran 1248 DSLAM to see if any of the sub-tended clients in the stack are communicating or not.

Ascend CSU [.zip]
Shows errors on an Ascend CSU.

Adtran CSU [.zip]
Monitors an Adtran CSU.

Tut Systems XL-4000 Campus Modem [.zip]
Monitors the status of a Tut Systems campus modem.





 

 
Switch Monitoring Probes

Switch/Firewall/Router probes developed by the InterMapper User Community include:

BGP Peering Session Probe [.zip]
Monitors the status of a particular BGP peering session on a Juniper or Cisco router, and generates alarms when the BGP session goes down.

Nortel Passport and Accelar Switches [.zip]
Monitors the CPU, Switch Fabric, and Buffer utilization of a Passport 8600 router.

Juniper EX-Series [.zip] [ view ]
Provides Informational, Tables, Resource Usage and Hardware Health information for Juniper EX-Series switches.

3Com 5500 switch [.zip]
Polls each interface of a 3Com 5500 switch, displays the current traffic in and out of each interface in kilobytes/second, and generates an alert if traffic on the monitored interface exceeds thresholds defined in the probe. This probe currently can only monitor one interface at a time.

Astrocom [.zip]
Polls each interface of an Astrocom device, displays the current traffic in and out of that interface in kilobytes/second, and generates an alert if traffic on the monitored interface exceeds thresholds defined in the probe. This probe currently can monitor up to three interfaces at a time.

High Traffic - PPS Probe [.zip]

Monitors traffic in packets per second, instead of bytes per second. This probe will provide a notification when traffic on a certain port/interface exceeds thresholds and give alarms when that interface goes down.

Tipping Point Intrusion Detection System (IPS) [.zip]
Monitors CPU, memory, critical log messages, and the number of passed/blocked packets for a TippingPoint IPS.

Juniper Netscreen SSG [.zip]
Monitors the CPU and Memory utilization of a Juniper Netscreen SSG security appliance using variables from NS-RES.

Nortel Ping Proxy [.zip]
Tells a Nortel device to ping the specified address, and returns whether the ping succeeded.

High Traffic Probe [.zip]
Gives a notification when traffic on a certain port/interface exceeds thresholds. Revised to give alarms if that interface goes down.


 

 
Storage Monitoring Probes

Storage monitoring probes developed by the InterMapper User Community include:

NetApp 3050c Probe [.zip]
Retrieves useful status variables about a NetApp 3050c filer. The probe assumes that the filer is clustered.

Dell EqualLogic iSCSI SAN [.zip] [ view ]
Provides Informational, Tables, Disk Usage, and Hardware Health information for Dell EqualLogic iSCSI SAN devices.


 

 
<< Start < Prev 1 2 3 Next > End >>

Page 1 of 3